STUDI PENDAHULUAN BATAS MAKSIMUM KADAR LUMPUR PADA AGREGAT BETON GEOPOLIMER

Authors

  • Djedjen Achmad Jurusan Teknik Sipil, Politeknik Negeri Jakarta
  • Desi Supriyan Jurusan Teknik Sipil, Politeknik Negeri Jakarta

DOI:

https://doi.org/10.32722/pt.v18i1.1283

Abstract

ABSTRACT


Has been researched the impact of mud in aggregate on geopolymer concrete with studies using the cement concrete as a reference. In this study both of concrete are mixed with a variation of mud of 0%, 0.75%, 3% and 5.75% of the combined aggregate weight. Compressive strength of cement concrete is designed with a target of 300 kg / cm2 and geopolymer concrete is made with water binder ratio (w/b) 0.25, Molarity 12 M, the ratio of sodium silicate and sodium hydroxide 1.5. At the age of 3, 7, 14 and 28 day tested of compressive strength, while the spliting test, flexural tensile strength, and modulus of elasticity are tested at 28 days. From the test results, the higher mud content in aggregate , the mechanical properties of the concrete are decreased. Based on testing of compressive strength in cement concrete at 28 days, with a 3% mud content (the content of the reference mud) turns of compressive strength decreased by 77.356%. Of the percentage reduction on the compressive strength of the cement concrete, can be compared to the mud content in geopolymer concrete at 2.04%. Thus the maximum mud on geopolymer concrete aggregate is, for coarse aggregate of 0.68% and a maximum mud content for fine aggregate was 3.4%.


Key words : Mud, aggregate, concrete, cement, geopolimer, strength


ABSTRAK


Telah diteliti dampak kadar lumpur pada agregat untuk beton geopolimer dengan penelitian menggunakan benda uji beton semen sebagai acuan dan beton geopolimer. Dalam penelitian ini ke dua beton tersebut dicampur dengan lumpur gabungan agregat kasar dan agregat halus dengan variasi 0 %, 0.75 %, 3 % dan 5,75 % dari berat agregat gabungan. Beton semen dirancang dengan target kuat tekan 300 kg/cm2 dan beton geopolimer dibuat dengan campuran water binder ratio (w/b) 0.25, Molaritas 12 M, perbandingan sodium silikat dan sodium hidroksida 1.5. Pada umur 3, 7, 14 dan 28 hari dilakukan uji kuat tekan, sedangkan uji kuat tarik belah, uji kuat tarik lentur, dan modulus elastisitas dilakukan pada umur 28 hari. Dari hasil uji terlihat bahwa semakin tinggi kadar lumpur pada agregat, karakteristik mekanis kedua beton tersebut mengalami penurunan. Berdasarkan pengujian kuat tekan pada beton semen umur 28 hari, dengan kadar lumpur 3 % (kadar lumpur referensi) ternyata beton semen mengalami penurunan kuat tekan sebesar 77.356 %. Dari persentase penurunan kuat tekan beton semen tersebut, diplot pada grafik kuat tekan beton geopolimer maka persentase kadar lumpur gabungan yang mengalami penurunan 77.356 % adalah 2.04 %. Dengan demikian kadar lumpur maksimum pada agregat beton geopolimer adalah, untuk agregat kasar sebesar 0.68 % dan kadar lumpur maksimum untuk agregat halus adalah 3.4 %.


Kata kunci : Lumpur, agregat, beton, semen, geopolimer, kekuatan

Downloads

Download data is not yet available.

References

Neville, Adam M. 1988. “Properties of Concrete“ 3rd Edition. Singapore: Longman Scientific and Technical.

Jose F. Muñoz, Dr. Isabel Tejedor, Dr. Marc A. Anderson, Dr. Steven M. Cramer. 2005. Effects of Coarse Aggregate Clay-Coatings on Concrete Performance, An IPRF Research Report, Innovative Pavement Research Foundation. University of Wisconsin-Madison.

Purwanto, Yulita Arni Priastiwi. 2012. Pengaruh Kadar Lumpur Pada Agregat Halus Dalam Mutu Beton, Jurnal Teknik – Vol. 33 No.2 Tahun 2012, ISSN 0852-16974, Fakultas Teknik Universitas Diponegoro.

SK SNI S-04-1989-F (Spesifikasi Bahan Bangunan Bagian A).

Olanitori, L.M. 2006. Mitigating The Effect Of Clay Content Of Sand On Concrete Strength [abstrak], 31st Conference On Our World In Concrete & Structures: 16 – 17 August, Singapore.

ASTM C-117 (Standard Test Method for Materials Finer than

-μm (No. 200) Sieve in Mineral Aggregates by Washing).

Davidovits, J. 1994. “Properties of Geopolimer“. France: Geopolimer Institute.

Published

2019-02-05

How to Cite

Achmad, D., & Supriyan, D. (2019). STUDI PENDAHULUAN BATAS MAKSIMUM KADAR LUMPUR PADA AGREGAT BETON GEOPOLIMER. Jurnal Poli-Teknologi, 18(1). https://doi.org/10.32722/pt.v18i1.1283

Issue

Section

Articles