Perancangan Fin-tube Surface Cleaning System Untuk Pembersihan Air-Cooled Heat Exchanger
DOI:
https://doi.org/10.32722/jmt.v4i2.5811Keywords:
piping systemm, fouling, preventive maintenance, nozzleAbstract
Maintenance cleaning of the outer surface of the fin-tube on air-cooled heat exchangers is essential to maintain optimal performance. Performance degradation occurs due to the accumulation of dust and impurities on the fin-tube surface, forming crusty deposits when exposed to water. Currently, manual cleaning using water spray takes 80 hours to cover the entire surface. To improve cleaning efficiency, an innovative design of a water flow system using pipes and nozzles was developed. The design was based on calculations using Bernoulli's law and simulations with Ansys Fluent. The design achieved sufficient working pressure and nozzle inlet velocity of 0,37 m/s for 648 nozzles to cover 18 fans. With this design, cleaning can be completed in 59 minutes, removing 2,40×10-8 kg of dust per nozzle, covering a cleaning area of 0,75 m2. The cleaning system is manually operated in monthly stages, requiring a total cleaning time of 17,70 hours. Effective cleaning is achieved by ensuring the fans are not in operation during the cleaning process.
References
T. Lestina, in Handbook of Thermal Science and Engineering (Springer International Publishing, Cham, 2017), pp. 1–33.
Mitsubishi Hitachi Power Systems, (2019).
H. V. Inamdar, E. A. Groll, J. A. Weibel, and S. V. Garimella, International Journal of Refrigeration (2023).
A. Abdulah, A. Djafar Shieddieque, D. Ardi Rajab, C. Anwar, and K. Utama, 42, (n.d.).
D. Prostański, Journal of Sustainable Mining 12, 29 (2013).
T. R. Bott and C. R. Bemrose, J Heat Transfer 105, 178 (1983).
T. R. Bott, Fouling of Heat Exchanger (Elsevier, New York, 1995).
Y. Sun, Y. Zhang, D. Barker, F. Steve, and M. Johnson, ASHRAE Trans (2012).
R. A. Parisher and R. A. Rhea, Pipe Drafting and Design, 2nd ed. (Gulf Professional Pub, Boston, 2002).
D. J. Whistance and D. R. Sherwood, The Piping Guide For The Design and Drafting of Industrial Piping Systems, 1st ed. (United States, 1973).
E. S. Menon, Piping Calculations Manual (McGraw-Hill, New York, 2005).
I. G. Rasagama, R. F. Muldiani, and K. Hadiningrum, PROSIDING SEMINAR NASIONAL FISIKA (E-JOURNAL) 5, (2016).
D. Zhuang, G. Ding, Y. Yang, F. Zhan, Y. Gao, and J. Song, International Refrigeration and Air Conditioning (2018).
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2023 Ijlal Syaifullah, Ratu Fenny Muldiani, Teguh Sasono
![Creative Commons License](http://i.creativecommons.org/l/by-sa/4.0/88x31.png)
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Jurnal ini berlisensi Atribut Berbagi Serupa 4.0 Internasional (CC BY-SA 4.0)
Anda diperbolehkan:
- Berbagi — menyalin dan menyebarluaskan kembali materi ini dalam bentuk atau format apapun;
- Adaptasi — menggubah, mengubah, dan membuat turunan dari materi ini untuk kepentingan apapun, termasuk kepentingan komersial.
Berdasarkan ketentuan berikut:
-
Atribusi — Anda harus mencantumkan nama yang sesuai, mencantumkan tautan terhadap lisensi, dan menyatakan bahwa telah ada perubahan yang dilakukan. Anda dapat melakukan hal ini dengan cara yang sesuai, namun tidak mengisyaratkan bahwa pemberi lisensi mendukung Anda atau penggunaan Anda.
-
BerbagiSerupa — Apabila Anda menggubah, mengubah, atau membuat turunan dari materi ini, Anda harus menyebarluaskan kontribusi Anda di bawah lisensi yang sama dengan materi asli.
- Tidak ada pembatasan tambahan — Anda tidak dapat menggunakan ketentuan hukum atau sarana kontrol teknologi yang secara hukum membatasi orang lain untuk melakukan hal-hal yang diizinkan lisensi ini.