Analysis of Fault Locations Using the Impedance Method on the GIS 150 kV Transmission Line Karang Pilang Surabaya
DOI:
https://doi.org/10.32722/pt.v23i2.6837Abstract
Transmission lines often experience difficulties in determining the location of interference, due to the length of the transmission line. This interference can be secured by using relays, one of which is a distance relay, this tool secures the zone 1, zone 2 and zone 3 areas on the transmission line. Apart from relays, there is also a tool to determine the fault distance, namely a fault locator. These two tools are examples of protection on transmission lines. The method used in this research uses the impedance method to determine the distance the fault occurs and the settings on the distance relay. This technique is often used in electric power systems and is very effective for transmission lines, such as those in Karang Pilang, because of its ability to detect disturbances in transmission lines and equipment. Based on the analysis results, calculating the fault distance using the impedance method shows that the calculated value is very close to the distance measured by the fault finder. Specifically when a short circuit occurs, the impedance method calculates a distance of 14.35 km, while the fault locator measures it at 14.59 km with a margin of error of 1.5%.
Downloads
References
Widagdo, R. S., Andriawan, A. H., Slamet, P., Budiono, G., Wardah, I. A., & Hartayu, R. (2023, November). Harmonic Mitigation Using Passive Filters in 3-Phase Inverters to Improve Power Quality on Microgrid. In 2023 International Conference on Advanced Mechatronics, Intelligent Manufacture and Industrial Automation (ICAMIMIA) (pp. 295-300). IEEE.
Widagdo, R. S., Slamet, P., Andriawan, A. H., Hariadi, B., Wardah, I. A., & Hartono, E. D. (2024). Assessment of Power System Equipment to Enhance the Power Quality at Dr. Saiful Anwar General Hospital Malang. BERNAS: Jurnal Pengabdian Kepada Masyarakat, 5(2), 1596-1604.
Widagdo, R. S., & Andriawan, A. H. (2023). Prediction of Age Loss on 160 KVA Transformer PT. PLN ULP Kenjeran Surabaya using The Linear Regression Method. Jurnal Riset Rekayasa Elektro, 5(2), 83-92.
De Aguiar, R. A., Dalcastagnê, A. L., Zürn, H. H., & Seara, R. (2018). Impedance-based fault location methods: Sensitivity analysis and performance improvement. Electric Power Systems Research, 155, 236-245.
Doria-García, J., Orozco-Henao, C., Leborgne, R., Montoya, O. D., & Gil-González, W. (2021). High impedance fault modeling and location for transmission line✰. Electric Power Systems Research, 196, 107202.
Mirshekali, H., Dashti, R., Keshavarz, A., Torabi, A. J., & Shaker, H. R. (2020). A novel fault location methodology for smart distribution networks. IEEE Transactions on smart grid, 12(2), 1277-1288.
Abbas, A. K., & Al-Tak, M. A. A. (2021). A review of methodologies for fault location techniques in distribution power system. Iraqi J. Electr. Electron. Eng, 17(2), 27-37.
Dashti, R., Daisy, M., Mirshekali, H., Shaker, H. R., & Aliabadi, M. H. (2021). A survey of fault prediction and location methods in electrical energy distribution networks. Measurement, 184, 109947.
Biswal, M., Ghore, S., Malik, O. P., & Bansal, R. C. (2021). Development of time-frequency based approach to detect high impedance fault in an inverter interfaced distribution system. IEEE Transactions on Power Delivery, 36(6), 3825-3833.
Sarwar, M., Mehmood, F., Abid, M., Khan, A. Q., Gul, S. T., & Khan, A. S. (2020). High impedance fault detection and isolation in power distribution networks using support vector machines. Journal of King Saud University-Engineering Sciences, 32(8), 524-535.
Hidayatullah, K., Hartati, R. S., & Sukerayasa, I. W. (2019). Analisis Penentuan Setting Distance Relay Penghantar SUTT 150 kV Gis Pesanggaran–Gi Pemecutan Kelod. Jurnal SPEKTRUM Vol, 6(1).
Anshar, C. N., & Budiman, B. (2022). Studi Analisa Arus Gangguan Hubung Singkat Berdasarkan Lokasi Titik Gangguan Pada Saluran Udara Tegangan Menengah 20 kV. Jurnal Teknik, Komputer, Agroteknologi Dan Sains, 1(1), 140-149.
Faritto, F., & Yulisman, Y. (2022). Analisa Penentuan Titik Lokasi Gangguan Pada Rele Jarak Menggunakan Metode Impedansi. Ensiklopedia Research and Community Service Review, 1(3), 93-99.
Nurdiana, N. (2016). Analisa Gangguan Arus Hubung Singkat Pada Penyulang Nakula Gardu Induk Talang Kelapa. Jurnal Ampere, 1(1), 26-36.
Khoa, N. M., Cuong, M. V., Cuong, H. Q., & Hieu, N. T. T. (2022). Performance comparison of impedance-based fault location methods for transmission line. International Journal of Electrical and Electronic Engineering & Telecommunications, 11(3), 234-241.
Personal, E., García, A., Parejo, A., Larios, D. F., Biscarri, F., & León, C. (2016). A comparison of impedance-based fault location methods for power underground distribution systems. Energies, 9(12), 1022.
Dashti, R., Daisy, M., Shaker, H. R., & Tahavori, M. (2017). Impedance-based fault location method for four-wire power distribution networks. IEEE Access, 6, 1342-1349.
Sa’ad Ahmed, S., Ismaeel, I., & Karam, K. M. (2020). Fault detection and location of power transmission lines using intelligent distance relay. International Journal of Power Electronics and Drive Systems, 11(2), 726.
Zamora-Mendez, A., Sotelo-Castañón, J., Paternina, M. R. A., Buendia, P., Torres, C., Toledo-Santos, C., ... & Mejia-Ruiz, G. E. (2021). Two effective methods for impedance estimation in distance relays based on the DC offset removal. Electric Power Systems Research, 194, 107102.
Hong, J. S., Sim, G. D., Choi, J. H., Ahn, S. J., & Yun, S. Y. (2020). Fault location method using phasor measurement units and short circuit analysis for power distribution networks. Energies, 13(5), 1294.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2024 Reza Sarwo Widagdo, Gatut Budiono, Aris Heri Andriawan, Puji Slamet, Roy Wibatsu Putra (Author)

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.