KUALITAS DAN KENYAMANAN UDARA PADA GEDUNG PERKANTORAN BERTINGKAT RENDAH DENGAN STUDI KASUS GEDUNG PERKANTORAN PT. X DI JAKARTA

##plugins.themes.academic_pro.article.main##

Putri Nur Ratnasari
Dyah Nurwidyaningrum

Abstract

Green Building Council Indonesia (GBCI) publishes an assessment device called Greenship to be used as a benchmark in planning to maintain green buildings. PT. Medtek one of the low-rise office buildings in Jakarta that is an area with moderate air pollution level based on air Pollution Standard Index (ISPU) which has no effect on human or animal health but influential on sensitive plants and aesthetic values. This research aimed to know the criteria points obtained by PT. Medtek,  influence of air quality, and building conditions in the user of the building.  Measurements of indoor air health, comfort and questionnaire data collection is done indoors when user’s activity in an office building is underway. The method used is a comparison method by comparing the results of field measurements with Greenship Rating Tools Existing Building version 1.1. The criteria achieved by PT. Medtek are a non-smoking campaign, outside air introduction, cigarette smoke control, and visual comfort. Criterion points earned 12 out of 18 scoring points are reviewed or meet 66.67% of the total assessment aspect of quality and comfort of indoor air.


Keywords: Green Building, Greenship, Air Pollution, Air Quality, Low-Rise Office.

##plugins.themes.academic_pro.article.details##

References

  1. M. R. A. Simanjuntak dan R. B. H. Manik, “KAJIAN AWAL SISTEM MANAJEMEN PENGENDALIAN MUTU DALAM MENINGKATKAN KINERJA WAKTU PROSES KONSTRUKSI BANGUNAN GEDUNG TINGGI HUNIAN DI DKI JAKARTA,” hal. 258–264, 2019.
  2. M. Fauzan dan A. Dyah, “Perancangan Rental Office Di Jakarta Dengan Penerapan Arsitektur Futuristik,” Maestro, vol. 2, no. 1, hal. 109–115, 2019.
  3. S. Pratiwi, “PENGGUNAAN DATA SATELIT GIOVANNI DALAM PEMANTAUAN KUALITAS UDARA,” hal. 1–5, 2019.
  4. S. Hastutiningrum, S. Sunarsih, dan Imelda, “Analisis Hubungan Aktivitas Kendaraan Bermotor Terhadap Konsentrasi So2 Dan No2 Di Udara Ambien (Studi Kasus: Jl. Panembahan Senopati Yogyakarta),” J. Teknol. Technoscientia, vol. 11, no. 1, hal. 85–94, 2018.
  5. “Kualitas Udara Dalam Ruang Perpustakaan Universitas ”X” Ditinjau Dari Kualitas Biologi, Fisik, Dan Kimiawi *),” Makara Seri Kesehat., vol. 12, no. 2, hal. 76–82, 2008.
  6. S. Handayani dan F. Suryani, “PENERAPAN VALUE ENGINEERING PADA PROYEK BANGUNAN GEDUNG BERDESAIN GREEN BUILDING DENGAN MEMBANDINGKAN PENGGUNAAN,” vol. 2, no. 1, hal. 7–10, 2018.
  7. Anisah, I. Inayati, F. X. N. Soelami, dan R. Triyogo, “Identification of Existing Office Buildings Potential to Become Green Buildings in Energy Efficiency Aspect,” Procedia Eng., vol. 170, hal. 320–324, 2017.
  8. M. S. A. Barra Pasuka Dewa, Agung Murti Nugroho, “Kajian Green Building Pada Gedung Dekanat Fakultas Teknik Universitas Brawijaya Malang,” 2012.
  9. Mulyono, “Petunjuk Standarisasi Desain Gedung Bertingkat,” Gancea Exact, 2000.
  10. E. Prianto dan B. Sujono, “SEMARANG,” vol. II, no. 1, hal. 81–98, 2017.
  11. J. G. Allen, P. MacNaughton, J. G. C. Laurent, S. S. Flanigan, E. S. Eitland, dan J. D. Spengler, “Green Buildings and Health,” Curr. Environ. Heal. reports, vol. 2, no. 3, hal. 250–258, 2015.
  12. A. Steinemann, P. Wargocki, dan B. Rismanchi, “Ten questions concerning green buildings and indoor air quality,” Build. Environ., vol. 112, no. 2017, hal. 351–358, 2017.
  13. Green Building Council Indonesia, “Greenship Existing Building Version 1.1,” 2016.
  14. R. L. Hedrick et al., “Ventilation for Acceptable Indoor Air Quality ASHRAE Staff Liaison : Mark Weber,” vol. 2013, 2013.
  15. P. A. T.A. Fikriyah, “Konsep Green Building Pada Bangunan Kantor Spazio, Surabaya,” Fak. Tek. Univ. Brawijaya, hal. 1–8, 2016.
  16. A. Sarinda, Sudarti, dan Subiki, “Analisis Perubahan Suhu Ruangan Terhadap Kenyamanan Termal di Gedung 3 Fkip Universitas Jember,” J. Pembelajaran Fis., vol. 6, no. 3, hal. 305–311, 2017.
  17. Anonim, Nilai Ambang Batas ( NAB ) Zat Kimia di Udara Tempat Kerja. 2005.
  18. C. I. Prasasti, J. Mukono, dan Sudarmaji, “Pengaruh Kualitas Udara Dalam Ruangan Ber -AC Terhadap Gangguan Kesehatan,” Kesehat. Lingkung., vol. 1, no. 2, hal. 160–170, 2005.
  19. A. K. Surakarta et al., “Penerapan Prinsip Arsitektur Hijau pada Bangunan Kantor Sewa di Surakarta,” vol. 2, no. 2, hal. 415–424, 2019.
  20. Anonim, Konservasi Energi pada Sistem Pencahayaan. 2000.
  21. Anonim, Spesifikasi Tingkat Bunyi dan Waktu Dengung dalam Bangunan Gedung dan Perumahan. 2000.